Options
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer
Built-in Wifi
ECG
Lead Mode Ā Ā Ā Ā Ā 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
Lead selectionĀ Ā Ā Ā Ā I, II, III, avR, avL, avF, V,
WaveformĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 2 ch
Lead mode Ā Ā Ā Ā Ā 3 Leads ( R, L, F or RA, LA, LL)
Lead selection Ā Ā Ā I, II, III,
WaveformĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1 ch
Gain           “2.5mm/mV, “5.0mm/mV, “10mm/mV, “20mm/mV
HR and Alarm
RangeĀ Ā Ā Ā Ā
AdultĀ Ā Ā Ā Ā Ā Ā Ā 30 ~ 300 bpm
Neo/Ped Ā Ā 30 ~ 350 bpm
Accuracy              ±1% or ±1bpm, which great
Resolution Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1 bpm
Sensitivity Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā > 200 uV P-P
Differential Input Impedance Ā > 5 MĪ©
CMRR
Monitor Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā > 105 dB
Operation Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā > 105 dB
Diagnosis Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā > 85 dB
Electrode offset potential ±300mV
Leakage CurrentĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā < 10 uA
Baseline Recovery Ā Ā Ā Ā Ā Ā < 10 sĀ After Defi.
ECG Signal Range       ±8 mV (Vp-p)
BandwidthĀ Ā Ā
Surgery Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1 ~ 15 Hz
Monitor Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 0.5 ~ 35 Hz
Diagnostic Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 0.05 ~ 100 Hz
Calibration Signal 1 mV (Vp-p), ±5% Accuracy
ST Segment Monitoring RangeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā
Measure and AlarmĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -2.0 ~ +2.0 mV
ARR DetectingĀ Ā Ā Ā Ā Ā
TypeĀ Ā Ā Ā Ā Ā ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Available
Review Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Available
Tall T-wave rejection capability Ā Ā 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display Ā Ā Ā Ā 1s
Heart rate meter accuracy and response to irregular rhythmļ¼
Bigeminy ventricular Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 80bpm
Bigeminy ventricular alternative lenteĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 57 or 63bpm
Bigeminy ventricular alternative rapid Ā Ā Ā Ā Ā Ā Ā 122 or 123bpm
Systoles bidirectional Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 95bpm
Response time to heart rate meter to change in heart rateĀ 80 to 120bpm
Average Ā Ā Ā Ā Ā 3.7s
Range Ā Ā Ā Ā Ā Ā 3.2s ~ 4.1s Ā 80 to 40bpm
AverageĀ Ā Ā Ā Ā Ā Ā Ā Ā 4.7s
NIBP
Method Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Oscillometric
ModeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Manual, Auto, STAT
Measuring Interval in AUTO Mode Ā Ā Ā Ā Ā 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960Min
Measuring Period in STAT Mode Ā Ā Ā Ā Ā Ā Ā 5 Min
Pulse Rate Range Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 40 ~ 240 bpm
Alarm Type Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā SYS, DIA, MEAN
Measuring and alarm Range
Adult Mode
SYS Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 40 ~ 270 mmHg
DIA Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 10 ~ 215 mmHg
MEANĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 20 ~ 235 mmHg
Pediatric Mode
SYS Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 40 ~ 200 mmHg
DIA Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 10 ~ 150 mmHg
MEAN Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 20 ~ 165 mmHg
Neonatal Mode
SYS Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 40 ~ 135 mmHg
DIA Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 10 ~ 100 mmHg
MEAN Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 20 ~ 110 mmHg
ResolutionĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā
PressureĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1mmHg
Accuracy
Pressure
Maximum Mean error        ±5mmHg
Maximum Standard deviation  ±8mmHg
Overpressure Protection
Adult Mode             297±3 mmHg
Pediatric Mode          240±3 mmHg
Neonatal Mode          147±3 mmHg
TEMPERATUREĀ
Channel Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 2
Measuring and Alarm Range  0 ~ 50 °C
Resolution                 0.1°C
Accuracy                 ±0.1°C
Actualization interval Ā Ā Ā Ā Ā Ā Ā about 1 Sec.
Average Time Constant Ā Ā Ā Ā Ā < 10 Sec.
IBPĀ (optional)
Channel Ā Ā Ā Ā 2
Label Ā Ā Ā Ā Ā Ā Ā ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm rangeĀ
ARTĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 0~300mmHg
PAĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -6~120mmHg
CVP/RAP/LAP/ICPĀ Ā -10~40mmHg
P1~P2Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -10~300mmHg
Press Sensor
SensitivityĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 5 uV/V/mmHg
ImpedanceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 300-3000Ī©
Resolution Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1mmHg
Accuracy                ±2% or 1mmHg which great
Actualization Interval Ā Ā Ā Ā Ā Ā about 1 Sec
Display
Device
12.1 in.Ā Color TFTĀ Made by Sharp Japan
MessagesĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā
7 Waveforms Maximum
1 Alarm LEDĀ ( Yellow/Red)
1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode
Signal InterfaceĀ Ā
ECG OutputĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā BNC
Amplitude Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 1 V/mV
AccuracyĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā < 5 %
ImpedanceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 50 Ī©
Signal DelayĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā < 20 mS
Recall
Trend Recall
ShortĀ Ā Ā 1 hrs, 1 Second Resolution
LongĀ Ā Ā Ā 72 hrs,Ā Ā 1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.
BatteryĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 48 mm
Paper SpeedĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 25/50 mm/S
TraceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 2
Size and Weight
SizeĀ Ā Ā Ā Ā Monitor Ā Ā Ā Ā Ā Ā Ā Ā Ā 310 x 140 x 263Ā mm
Weight Monitor Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 3.8Ā kg
Standard:
ECG Cable (5 Leads) …… 1Pcs
SpO2 Cable (Adult) …….. 1Pcs
TEMP Probe (Adult) ……. 1Pcs
NIBP Cuff (Adult) ………… 1Pcs
NIBP Tube(150cm) ……… 1Pcs
Ground Cable ……………. 1Pcs
Power Cable ………………. 1Pcs
Cleaning Cloth ……………. 1Pcs
Options:
ECG Cable (3 Leads)
ECG Alligator Clips (Metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (infant 8 – 14 cm 5/Bag)
NIBP Cuff (Child 13 – 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
NIBP Cuff (Adult 26 – 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
NIBP Cuff (Thigh 42 – 50 cm)
NIBP Tube 150cm
Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
EtCO2 Module
CO2 Sample Line
Nasal Tube
Water-trap Column
Airway Adapter
IBP Adapter (2-IBP)
IBP Reusable Interface Cable
IBP Disposable Transducers