MD9000s Patient Monitor 12 Inch Color TFT Screen with Printer

FREE SHIPPING! Delivery in 3 Days

MD9000s patient monitor has a 12.1″color TFT screen.
Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options.

Original price was: £1,270.00.Current price is: £970.00.

Guaranteed Safe Checkout

Features & Compatibility

12.1” TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
All-round monitor for adult, pediatric and neonate.
With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
Finish all operations by keys and knobs.
Maximum 8-channel waveform synchronous display.
Display 7-lead ECG waveform on one screen, cascade ECG waveform display
Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
Heart rate variability (HRV) analysis function
NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
Drug concentration calculation and titration table functions.
One-touch printing of trend graph
Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).

Options
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Masimo SpO2 Module
Thermal Printer
Built-in Wifi

 

ECG
Lead Mode Ā  Ā  Ā  Ā  Ā  5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
Lead selectionĀ Ā Ā Ā Ā  I, II, III, avR, avL, avF, V,
WaveformĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  2 ch
Lead mode Ā  Ā  Ā  Ā  Ā  3 Leads ( R, L, F or RA, LA, LL)
Lead selection Ā  Ā  Ā I, II, III,
WaveformĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  1 ch
Gain                     “2.5mm/mV, “5.0mm/mV, “10mm/mV, “20mm/mV
HR and Alarm

RangeĀ Ā Ā Ā Ā 
AdultĀ Ā Ā Ā Ā  Ā Ā Ā  30 ~ 300 bpm
Neo/Ped Ā  Ā 30 ~ 350 bpm
Accuracy                           ±1% or ±1bpm, which great
Resolution Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  1 bpm
Sensitivity Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  > 200 uV P-P
Differential Input Impedance Ā > 5 MĪ©
CMRR
Monitor Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā > 105 dB
Operation Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  > 105 dB
Diagnosis Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  > 85 dB
Electrode offset potential  ±300mV
Leakage CurrentĀ  Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  < 10 uA
Baseline Recovery Ā  Ā  Ā  Ā  Ā  Ā < 10 sĀ  After Defi.
ECG Signal Range            ±8 mV (Vp-p)

BandwidthĀ Ā Ā 
Surgery Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 1 ~ 15 Hz
Monitor Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 0.5 ~ 35 Hz
Diagnostic Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  0.05 ~ 100 Hz
Calibration Signal  1 mV (Vp-p),  ±5%  Accuracy

ST Segment Monitoring RangeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
Measure and AlarmĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  -2.0 ~ +2.0 mV

ARR DetectingĀ Ā Ā Ā Ā Ā 
TypeĀ Ā Ā Ā Ā Ā  ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā Available
Review Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā Available
Tall T-wave rejection capability Ā  Ā 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display Ā  Ā  Ā  Ā 1s
Heart rate meter accuracy and response to irregular rhythm:
Bigeminy ventricular Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  80bpm
Bigeminy ventricular alternative lenteĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  Ā Ā Ā 57 or 63bpm
Bigeminy ventricular alternative rapid Ā  Ā  Ā  Ā  Ā  Ā  Ā 122 or 123bpm
Systoles bidirectional Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 95bpm
Response time to heart rate meter to change in heart rateĀ 80 to 120bpm
Average Ā  Ā  Ā  Ā  Ā 3.7s
Range Ā  Ā  Ā  Ā  Ā  Ā  3.2s ~ 4.1s Ā 80 to 40bpm
AverageĀ Ā Ā Ā Ā Ā Ā Ā Ā  4.7s

NIBP
Method Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Oscillometric
ModeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  Ā Ā Ā  Manual, Auto, STAT
Measuring Interval in AUTO Mode Ā  Ā  Ā  Ā  Ā  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960Min
Measuring Period in STAT Mode Ā  Ā  Ā  Ā  Ā  Ā  Ā 5 Min
Pulse Rate Range Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 40 ~ 240 bpm
Alarm Type Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  SYS, DIA, MEAN

Measuring and alarm Range
Adult Mode
SYS Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 40 ~ 270 mmHg
DIA Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  10 ~ 215 mmHg
MEANĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  20 ~ 235 mmHg
Pediatric Mode
SYS Ā Ā Ā Ā Ā Ā Ā Ā  Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 40 ~ 200 mmHg
DIA Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  10 ~ 150 mmHg
MEAN Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 20 ~ 165 mmHg
Neonatal Mode
SYS Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  40 ~ 135 mmHg
DIA Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 10 ~ 100 mmHg
MEAN Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 20 ~ 110 mmHg

ResolutionĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
PressureĀ Ā Ā Ā  Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  1mmHg
Accuracy
Pressure
Maximum Mean error               ±5mmHg
Maximum Standard deviation   ±8mmHg

Overpressure Protection
Adult Mode                        297±3 mmHg
Pediatric Mode                  240±3 mmHg
Neonatal Mode                  147±3 mmHg

TEMPERATUREĀ 
Channel Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  2
Measuring and Alarm Range   0 ~ 50 °C
Resolution                                0.1°C
Accuracy                                 ±0.1°C
Actualization interval Ā  Ā  Ā  Ā  Ā  Ā  Ā  about 1 Sec.
Average Time Constant Ā  Ā  Ā  Ā  Ā < 10 Sec.

IBPĀ (optional)
Channel Ā  Ā  Ā  Ā  2
Label Ā  Ā  Ā  Ā  Ā  Ā  Ā ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm rangeĀ 
ARTĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  0~300mmHg
PAĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  -6~120mmHg
CVP/RAP/LAP/ICPĀ Ā  -10~40mmHg
P1~P2Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  -10~300mmHg
Press Sensor
SensitivityĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  5 uV/V/mmHg
ImpedanceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  300-3000Ī©
Resolution Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  1mmHg
Accuracy                              ±2% or 1mmHg which great
Actualization Interval Ā  Ā  Ā  Ā  Ā  Ā about 1 Sec

Display
Device
12.1 in.Ā  Color TFTĀ  Made by Sharp Japan

MessagesĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
7 Waveforms Maximum
1 Alarm LEDĀ  ( Yellow/Red)
1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode

Signal InterfaceĀ Ā 
ECG OutputĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  BNC
Amplitude Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  1 V/mV
AccuracyĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  < 5 %
ImpedanceĀ Ā Ā Ā Ā Ā Ā Ā Ā  Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  50 Ī©
Signal DelayĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  < 20 mS

Recall
Trend Recall
ShortĀ Ā Ā  1 hrs, 1 Second Resolution
LongĀ Ā Ā Ā  72 hrs,Ā Ā  1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.

BatteryĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 48 mm
Paper SpeedĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  25/50 mm/S
TraceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā  2

Size and Weight
SizeĀ  Ā Ā Ā Ā  Monitor Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 310 x 140 x 263Ā  mm
Weight Monitor Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā  Ā 3.8Ā  kg

 

Standard:

ECG Cable (5 Leads) …… 1Pcs
SpO2 Cable (Adult) …….. 1Pcs
TEMP Probe (Adult) ……. 1Pcs
NIBP Cuff (Adult) ………… 1Pcs
NIBP Tube(150cm) ……… 1Pcs
Ground Cable ……………. 1Pcs
Power Cable ………………. 1Pcs
Cleaning Cloth ……………. 1Pcs

Options:

ECG Cable (3 Leads)
ECG Alligator Clips (Metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
SpO2 Cable (Pediatric hard shell sensor)
SpO2 Cable (Pediatric Soft shell sensor)
SpO2 Cable (Child finger clip)
SpO2 Cable (multi-site Y type)
SpO2 External Cable
NIBP Cuff (infant 8 – 14 cm 5/Bag)
NIBP Cuff (Child 13 – 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
NIBP Cuff (Adult 26 – 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
NIBP Cuff (Thigh 42 – 50 cm)
NIBP Tube 150cm
Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
EtCO2 Module
CO2 Sample Line
Nasal Tube
Water-trap Column
Airway Adapter
IBP Adapter (2-IBP)
IBP Reusable Interface Cable
IBP Disposable Transducers

 

Additional information

Customer Reviews

Reviews

There are no reviews yet.

Be the first to review “MD9000s Patient Monitor 12 Inch Color TFT Screen with Printer”